Hardware:Gamma Tech E-link Digitizer Installation
From OptiTexHelpEn
You should set the E-link through the E-link Control Center supplied with the E-link Digitizer.
Contents |
Installation Steps
- Run installation (figure 1-5).
- Connect the Digitizer and Computer (figure 6-7).
- Click on the 0 key of digitizer cursor and trun on the power of the Digitizer at same time.
- After hearing two beeps, open the E-link Control Center.
If OptiTex does not appear in the Gamma Tech application , use the settings that appear on the Digitizer manuel as combination No.19 (Format 1,2,5) = K±XXXXXSP±YYYYYCRLF K±XXXXXXSP±YYYYYYCRLF
PDS Settings
- Open the Digitizer Setup box
- Choose GTCO DIGI-PAD from the list - this will bring all the communication setting, you can check if they are as describe in the picture bellow by clicking on the 'Communication Parameters' button.
- Your COM port depends on you hardware configuration
- Elink digitizer comes in One size 36"X48"
5. Try the Digitizer mouse. Check if all the buttons work including the letters buttons. In case that some of them not function as you desired - try Numonuics as the driver format.